The total current draw for all the devices connected to the circuit cannot exceed the nac rating.
Fire alarm signal circuit.
A fire alarm notification appliance is an active fire protection component of a fire alarm system.
A condition which may be caused by an interruption of the data communication link or signalling line circuit caused by either an open circuit short circuit or device failure.
Each nac notification appliance circuit in a fire alarm panel or booster power supply has a maximum current rating.
If an open additional troubles may also be queued that relate to the failure of one or more active field devices from communicating their condition with the common control.
Initially all appliances were either electromechanical horns or electric bells which would later be replaced by electronic sounders.
9 6 fire detection alarm and communications systems.
Alarm supervisory trouble opens and grounds on a fire alarm circuit will result in a blank signal.
Trouble supervisory and alarm.
Signal circuit nac on a fire alarm panel.
For some more advanced systems the panel may indicate the kind of problem and where it is located.
Fire alarm circuit classes 2007 nfpa 72 6 4 2 1 class.
Most of today s appliances produce s.
A circuit where automatic or manual initiating devices are connected and the signal does not identify the individual device operated.
Initiating device circuits notification appliance circuits and signaling line circuits shall be permitted to be designated as either class a or class b depending on their performance during nonsimultaneous single circuit fault conditions as specified by the following.
Audible appliances have been in use longer than any other method of notification.
Performance shall be based upon wiring class note the old class style has been replaced with class only alarms must activate nacs and control circuits within 10 seconds.
Trouble signal a trouble signal is typically designated by a yellow light and means that there is an operational issue.
A notification appliance may use audible visible or other stimuli to alert the occupants of a fire or other emergency condition requiring action.
The signaling line circuit is used by the main computer fire alarm control panel or facp to communicate with all the sub computers detectors and modules.
9 6 fire detection alarm and communications systems.
The data sent from the facp to the detectors and modules carries information like address and polling and sometimes programming.
9 6 3 6 the general evacuation alarm signal shall operate in accordance with one of the methods prescribed by 9 6 3 6 1 through 9 6 3 6 3.
There are three basic categories for fire alarm panel signals.